Spectra Logic 10000 User Manual Page 83

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 82
Chapter 6. Maintaining the Library
83
MD S/N Drive information.
Revision Number Used only for diagnostic troubleshooting.
Drive S/N Drive serial number.
SCSI Bus Mode The mode sets the maximum data transfer rate.
Drive Switches Physical DIP switch configuration on the drive; the Emulate 1/2 and
Emulate 3/4 settings override the drive switch value.
Switch Override The drive configuration switch setting; confirm that this value matches
the values in the Emulate 1/2 and Emulate 3/4 configuration fields.
ECC Screens
The ECC1 and ECC2 screens display real-time error code correction information
compiled by the library when tapes finish unloading from a drive. If you enable ECC
Fault Check, an error report is sent to the host if drive error rates exceed certain levels.
To view the ECC screens:
1. Touch ECC1 on the Barcode screen or ER on the main screen to see the ECC1
screen.
2. From the ECC1 screen, touch ECC2 to see the ECC2 screen.
ECC Fault Check
The ECC fault check is a real-time error rate monitor. If you suspect that you may have
a tape problem or a drive problem, enable ECC Fault Check to check the performance
of the tape or the drive. When you enable ECC Fault Check, the library issues a Media
Warning error when certain conditions are met:
• More than 1,024 RAW retries per 1,024 groups written
• More than 11 read retries or 11 C3 (third-level ECC) errors per 1,000 groups read
The data for this warning is calculated using an average value of 1024 groups
(approximately 820 MB) of read or write data.
If the library displays a media warning, the data on the tape should be copied onto a
new tape, and the old tape should be discarded.
ECC Fualt Check is off by default. To enable ECC Fault Check:
1. Touch the + symbol to enable the ECC fault check to return an error report to
the host, or touch the - symbol to disable error reporting.
2. Touch Save Parms > No; it is not necessary to restart the library for these changes
to take effect.